Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
Why Maintain Ph 9 6 To11 5 boiler Drum-TOBO BOILER
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
When a boiler water test indicates a pH value of 6, you should _____. (a) chemically treat to raise the pH to normal level (b) check the DC heater for possible malfunction (c) begin a continuous boiler blow down (d) chemically treat to lower the pH to normal levelGet Price
What is the reason for keeping a boiler feed water pH lower than that Get Price
MVB Vertical Hydronic Boilers, 2503 - 4003 Time-honored technologies unite with cutting-edge advancements in Raypak's MVB modulating vertical boiler. Small space is no longer a problem, and our compact design fits through a 32" door opening to make it the perfect choice for those hard-to-reach retrofit projects.Get Price
What is the Difference Between Horizontal & Vertical Boiler Flues?Get Price
The phosphate-hydroxide or conventional treatment method is commonly used. It involves the addition of phosphate and caustic to boiler. The caustic is added to maintain a pH in the range 10.5–11.2. This practice is used in high-pressure boilers. In this process, calcium and magnesium salts are precipitated in a sludge form.Get Price
pre-boiler circuit as pH was increased. The data shown in Table 2 comes from a paper presented at this conference at an earlier date.3 Table 2: Iron release from BFW circuit as function of pH Day BFW pH BFW Iron, ppb (ųg/l), as Fe* 15 8.4 40 16 8.5 35 17 9.1 11 18 9.1 9 19 9.0 <5 20 9.0 6 21 9.1 <5 22 9.0 <5 23 9.0 <5 24 9.0 6Get Price
Jun 18, 2012 · Open-loop step testing as shown in Figure 5 can help provide this understanding. The feedwater valve is stepped while monitoring the response of the feedwater flow, boiler drum level, and steam flow. In the example shown in Figure 6, the feedwater flow does not respond well to changes in the feedwater valve at the points indicated by the red marks.Get Price
Aug 05, 2018 · The drum level controller compares the drum level measurement to the set point and modulates the feed-water control valves to keep the water level in the drum as close to set point as possible. 1. Integrating Process From a controls point-of-view, the boiler drum is an integrating process.Get Price
Aug 11, 2020 · While the common tap water pH value varies from 6.5 to 7.5, those bottled water sold as alkaline water claims their pH value from 8 to 9. So in this case, it is still safe to drink water or a beverage with a pH value between 6.5 to 9. Going back to Boiler water, the pH value should be controlled to pH 10.5 to 11. Why?Get Price
The pH should be maintained between a minimum of 10.5 and a maximum of 11.0 to prevent acidic corrosion of boiler tubes and plates, and to provide for the precipitation of scale forming salts before scale is deposited. Below a pH of 5.0 the water is …Get Price
In plants with sodium zeolite softened makeup water, automatic control systems can maintain boiler water conductivity within 5% of the set-point. Plant operating records have verified that with manual adjustment, continuous blowdown is within this 5% range no more than 20% of the time.Get Price
Aug 22, 1994 · Boiler systems containing copper alloys should have a condensate/feedwater pH within the range of 8.8 - 9.2. All-steel boiler systems are best protected when the condensate/feedwater pH is within the 9.2 - 9.6 range. A compromise condensate/feedwater pH control range of 8.8 to 9.2 is usually established where both metals are present.Get Price
Mar 17, 2015 · Step 5: Determine Fuel Energy. Fuel Energy = Boiler Energy / Combustion Efficiency [ Fuel Energy = 44,157 = 39,741 / 0.9 ] Assumptions. Deaerator provides feedwater near the boiling temperature for the deaerator's set operating pressure. (Saturated Liquid) Steam, Boiler, and Blowdown Pressure are the same.Get Price
Generally it is desirable to have a slightly high pH for boiler feed water. Ideally the feed water should be in the range of pH 8.5 – 9.5. This ensures that free carbon dioxide within the system becomes 'fixed'. If copper fed lines or heaters are used, restrict the feed water pH to …Get Price
Left: Rigi vertical-boiler locomotive: 1881. Built in 1873 by SLM of Winterthur for use on the Rigi Railway System in Switzerland, this is the oldest Swiss locomotive still surviving, and also the only standard-gauge vertical-boiler rack locomotive left in the world. It …Get Price
It is recommended that sodium to phosphate molar ratio (Na:PO 4 ) must be kept below 2.6 in this program, achieved by adding specific mixture of Na 3 PO 4 …Get Price
3 PART I DEFINITION OF TERMS l. ACT - The Boiler and Pressure Vessel Safety Act which was enacted as Chapter 28-25, Acts of the General Assembly. 2. ADMINISTRATOR - The Administrator of the Division of Occupational Safety is appointed by the Director of LaborGet Price
1. Priming - This is the ejection of boiler water into the steam take-off and is generally due to one or more of the following: -Operating the boiler with too high a water level. -Operating the boiler below its design pressure; this increases the volume and the velocity of the steam released from the water surface.Get Price
Maintaining the pH of boiler water in the range of 9–11 decreases the rate of corrosion; 9.2 to 9.8 is ideal. In low-pressure steam or hot water heating systems, nitrite or chromate provides a protective film on metal surfaces. Filming amines provide a physical barrier to protect metal from corrosion. They are effective in the pH range of 5.5 Get Price
Alkalinity is measured by titrating a water sample with a standard acid to a designated pH and is recorded as P, M, or T alkalinity. P alkalinity is titrated with p henolphthalein to pH 8.3, M alkalinity with m ethyl orange indicator to pH 4.6, and T alkalinity with t otal alkalinity indicator to pH 4.5. Once you know the values for P, M, or T Get Price
Ph And Phosphate Concentration In Bfw And Steam Drum - Industrial Get Price
To maintain boiler integrity and performance and to provide steam of suitable turbine or process purity, boiler feedwater must be purified and chemically conditioned. The amount and nature of feedwater impurities that can be accommodated depend on boiler operating pressure, boiler design, steam purity requirements, type of boiler water internal treatment, blowdown rate, and …Get Price
Jul 21, 2020 · That is we need to dose 0.85 kg of TSP in a day to maintain phosphate level & pH in drum water So phosphate dosing in mg/liter or ppm = 0.85 X 10 6 / (100*1000 X 24) =0.35 So per hour we have to dose (0.35 X 100 X 1000) / 1000 =35 gram of TSP into steam drum.Get Price
Why Maintain Ph 9 6 To11 5 Boiler Drum; Reliable Performance Coal Fired Szl Boiler; Why Steam Pressure Increases If Water Boiler Added; Steam Boilers Performance; High Performance Natural Gas Hot Water Boiler; High Performance Wood Chip Biomass Fired 2 Ton Biomass Boiler; Enhancing Biomass Boiler Firetube PerformanceGet Price
3 PART I DEFINITION OF TERMS l. ACT - The Boiler and Pressure Vessel Safety Act which was enacted as Chapter 28-25, Acts of the General Assembly. 2. ADMINISTRATOR - The Administrator of the Division of Occupational Safety is appointed by the Director of LaborGet Price
Ph And Phosphate Concentration In Bfw And Steam Drum - Industrial Get Price
Close boiler drains and openings with the exception of steam drum, superheater, and economizer vents. 3.3.5 Immediately fill the boiler, including superheater and economizer, taking suction from the carbohydrazide lay-up solution treated tank. 3.3.5.1 While filling the boiler, close each vent in turn as the treated water overflows.Get Price
Inferred pH in Steam Plant Water Chemistry Monitoring Introduction Background Inferred pH means pH calculated from straight and cation conductivity. The calculation can be applied to condensate, feedwater, and boiler water. Although not widely used in the United States, inferred pH is popular in Europe. Some plant chemists findGet Price
292 Chapter 14 Stack—an opening at the top of the boiler that is used to remove flue gas, p. 297. Steam drum—the top drum of a boiler where all of the generated steam is collected before entering the distribution system, p. 293. Steam trap—a device used to remove condensate or liquid from steam systems, p. 294. Superheated steam—steam that has been heated to a very …Get Price
In plants with sodium zeolite softened makeup water, automatic control systems can maintain boiler water conductivity within 5% of the set-point. Plant operating records have verified that with manual adjustment, continuous blowdown is within this 5% range no more than 20% of the time.Get Price