Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Save up to 50 to 80 Boiler Feedwater Treatment And on all

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Save up to 50 to 80 Boiler Feedwater Treatment And on all
  • Supply Capacity : 10 units/month :Save up to 50 to 80 Boiler Feedwater Treatment And on all
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Introduction to Condensate Recovery - Spirax Sarco

    The average boiler steaming rate is 15000 kg/h, and the plant operates for 8000 h/year. The fuel used is gas on a firm tariff of £0.011/ kWh, and the boiler efficiency is estimated as 80%. Make-up water temperature is 10°C and insulated condensate return lines ensure that condensate will arrive back at the boiler house at 95°C.Get Price

  • Boiler Operation; Feedwater treatment Flashcards - Cram.com

    Study Flashcards On Boiler Operation; Feedwater treatment at Cram.com. Quickly memorize the terms, phrases and much more. Cram.com makes it easy to get the grade you want! -Boiler must be above 50% output when sootblowers in use, except in air heaters 3 major areas of attention when starting up a boiler. Ignition. Boiler warm-up.Get Price

  • Power Plant Boiler Feed Water Treatment System Project

    In the raw water quality hardness of the region more popular boiler water treatment, so the power plant boiler make-up water treatment system is very important. 4. Solution. Using two-stage reverse osmosis, the Zhangze power plant boiler make-up …Get Price

  • Multiple Small Boilers vs One Large Boiler - Boiler and

    Apr 08, 2021 · If the process can not be off line while the boiler is off line for maintenance you may need to consider N+1 redundancy for all boiler house components. N+1 might also be applied to the inter connecting piping, control systems, etc. Your choices should consider the cost of being off line vs the extra cost of N+1 design.Get Price

  • "Save $91,000 Annually In Low Pressure Boiler Water

    8.0 – 8.5.The use of dealkalizer post softener can prevent up to 75-80% of the CO 2 formation in the condensate. The dealkalizer does this by removing the total alkalinity in the boiler make-up water before reaching the boiler. Total CO 2 Removal: 93.1lbs/day Chemical Savings: $209.48/day Chemical Savings: $76,460/yearGet Price

  • Power plant and calculations: Boiler feed pumps (BFP

    Jun 19, 2020 · NPSHa = Ha +- HZ - Hf + Hv - Hvp. Where, Ha is the absolute pressure on the surface of the liquid in the supply tank. HZ is vertical distance between the surface of the liquid in the supply tank and the center line of the pump. Hf is friction losses in the suction piping. Hv is Velocity head at the pump suction port.Get Price

  • Save up to 50% to 80% Boiler Feed Pump Failure And on all

    Boiler Feed Pump Failure Selections. Boiler Suits For Kids. 5 Ton Heat Pump Split System 16 Seer. Duraflame Electric Fireplace Insert W Heater. Coleman Furnace Blower Motor Wiring. Fireplace Insert Electric 29. Viaaqua Titanium Aquarium Heater 50-watt. Aquarium Heater 5 Gallon Adjustable. Aquarium Heater 300w Digital Tv.Get Price

  • Boiler Feedwater Systems | Deaerators - Indeck Power

    BOILER FEEDWATER DEAERATORS. From in-plant deaerator inspections, to use in conjunction with a rental boiler, to equipment expansion or replacement, Indeck's emergency water treatment trailers will provide the necessary flow rate and water …Get Price

  • Boiler Water Treatment - Association of Water Technologies

    clean boiler will save far more money in fuel than it could ever –Preheat Boiler Feed (Atmospheric Feed Water Tank) •195° - 205°F (0.1 – 1 ppm Oxygen) –Systems with 80% or more of make up do not require a surge tank –Systems with more than 20% condensateGet Price

  • Waster Heat Recovery Boiler Design Calculations

    A novel flue gas waste heat recovery system for coal. The thermal energy of exhaust flue gas dumped into the environment accounts for approximately 50%–80% of a boiler's thermal loss, and 3%–8% of the plant total energy input. Obviously, there exists a great potential to improve the efficiency of the power plant by the recovery of the waste Get Price

  • Study on the thermodynamics performance of industrial boiler

    Jul 14, 2014 · The boiler thermal efficiency is weakly effected by excess air ratio, unit load and fuel lower heating value varying from 90.3% -92.3% for wide range of above variables. Thus, in …Get Price

  • Boiler Services Phoenix AZ - Patriot Boiler

    Example: 100 HP boiler operating at 50% load, 75% efficiency, 24 hours a day, 5 days a week assuming natural gas cost at 1.00 per therm will cost $10,200 per month for fuel. By increasing the efficiency to just 80% you will save $510 per month for gas with an annual savings of approximately $6120.Get Price

  • Aquafilm Film Forming Agents | Watertech of America, …

    No mixing or diluting – reduces operator involvement by up to 80%. Reduces maintenance costs and prolongs equipment life. Simplifies water testing. Watertech of America distributes Aquafilm film forming agents. An innovative technology for boiler water treatment.Get Price

  • A Slippery Issue: Getting Your Arms Around Water Data - Energy

    • Typically 4 – 8% of boiler feedwater flow rate • Can be as high as 10% • Not all can be returned; ~10% lost as flash steam • Goal of 75-80% recovery is reasonable • 0.1 - 0.2% of feedwater flow *Feedwater Flow Rate = (Steam Mass Flow Rate /Get Price

  • Boiler Water Treatment Chemicals, Feed, and Control

    The total calculation equation to remove residual oxygen and provide a boiler water residual is: (Feedwater O 2 x 7.88) + (1.6 x Boiler Water SO 3 Residual) / Feedwater Cycles = Feedwater Dosage of sodium sulfite in ppm. Spreadsheets can be made as shown at the end of the article that illustrate theGet Price

  • Power plant and calculations: Boiler feed pumps (BFP

    Jun 19, 2020 · NPSHa = Ha +- HZ - Hf + Hv - Hvp. Where, Ha is the absolute pressure on the surface of the liquid in the supply tank. HZ is vertical distance between the surface of the liquid in the supply tank and the center line of the pump. Hf is friction losses in the suction piping. Hv is Velocity head at the pump suction port.Get Price

  • Strategies for reducing energy savings in large office

    Save up to 15% on energy costs. EndoTherm can be installed into ANY hydronic heating, process, and chilled loop system. A guide to understanding chemical water treatment in cooling and boiler water systems. A comparison of feedwater tanks and deaerators for storing and treating boiler feedwater.Get Price

  • DesaliTec SOAR CCRO

    Boiler Feed Water Cooling Tower Makeup Ingredient Water Process Water Desalination Water Reuse 8 | DesaliTec™ SOAR CCRO Water Solutions "Water is a critical commodity and a depleting resource in California. As one of the top water consumers in San Francisco, it is essential for us to do our part to minimize our impact to the city. The BARTGet Price

  • (PDF) Optimization of an Industrial Boiler Operation

    Economizers are the devices fitted to boiler and save energy by using the exhaust gasses of it to preheat the cold water used to fill it. Steam boilers use a massive amount of energy, rising feed water to the boiling temperature of it by converting the water steam and superheating that steam than the saturation temperature in the industry.Get Price

  • Boiler, Cooling and Wastewater Treatment Chemicals in

    Use make-up water that consists of at least 50% non-potable water, such as harvested rainwater, harvested storm water, air conditioner condensate, swimming pool filter backwash water, cooling tower blowdown, pass-through (once-through) cooling water, recycled treated waste water for toilet and urinal flushing, foundation drain water, municipally reclaimed water or any other …Get Price

  • Water Management in Oil Sands Mining Facilities | Oil

    Feb 25, 2016 · River water quality is exceptional good and is commonly used as boiler feed water in Utilities or even drinking water. RECYCLED WATER POND. The Recycled Water Pond also serves as a critical water storage facility. This pond sources about 80% of its water from the Tailings Pond and the balance from the Raw Water Pond (or Athabasca River Water Get Price

  • Easy to control and distribute

    18. De-aeration of boiler feed water is referred to as: a) removal of dissolved gases b) removal of silica c) removal of scales by blow down d) phosphate treatment of feed water 19. The percentage raise in boiler efficiency by a 20 degree centigrade raise in combustion air temperature is ___. a) 0.1% b) 0.2% c) 10% d) 1% 20.Get Price

  • Boiler Water Treatment Chemicals - Feedwater

    Boiler Water Treatment Chemicals. As well as being a service company Feedwater also manufactures and supplies a range of high-quality boiler water treatment chemicals for UK and export customers. Our chemicals are suitable for land, marine and heritage steam boilers.. A badly treated steam boiler is a potential bomb, so getting the feed water quality and boiler water …Get Price

  • Clean Firetube Boiler Waterside Heat Transfer Surfaces

    Visually inspect boiler tubes when the unit is shut down for maintenance. Scale removal can be achieved by mechanical means or acid cleaning. If scale is pres-ent, consult with your local water treatment specialist and consider modifying your feedwater treatment or …Get Price

  • Waste-to-energy: Coupling Waste Treatment to Highly

    The feasibility of strongly reduced boiler-end temperatures is then illustrated with experience from medium-scale plants operating with boiler feedwater temperatures as low as …Get Price

  • Boiler Feedwater Treatment (Part II): Water Treatment

    For example if a particular boiler can tolerate 500 ppm maximum dissolved solids, and the feedwater contains 50 ppm, it can be concentrated only about 10 times. This means that for every 100 pounds of water fed to the boiler about 10 pounds of boiler water must be blown down to keep the dissolved solids from exceeding 500 ppm.Get Price

  • Boiler Blowdown Control | Eurotherm by Schneider Electric

    A boiler, operating at 80% efficiency, has a maximum evaporation rate of 5,000kg/hr at 10 bar and receives feedwater at 70°C. Of the 5,000kg/hr, 4,500kg/hr of steam is exported and 500kg/hr is lost through blowdown. Using steam tables, the heat content of …Get Price

  • Boiler, Cooling and Wastewater Treatment Chemicals in

    Watertech of America provides water treatment chemicals for boiler feedwater, cooling water, Save up to 15% on energy costs. EndoTherm can be installed into ANY hydronic heating, process, and chilled loop system. Strategies for reducing energy savings in …Get Price

  • Why Use Reverse Osmosis for Boiler Feedwater in Corrugators?

    Aug 10, 2021 · Boiler feedwater quality impacts the purity of the steam. If your job is keeping production on track, you know all too well steam purity in turn affects the corrugator's speed and efficiency. All that to say, the boiler pretreatment equipment you enlist to do the job is essential to improving boiler steam quality and avoiding scaling or foaming.Get Price

  • Boiler Treatment Chemicals - Therminol 55 Boiler Chemicals

    ACUTHERM 3301 is a high performance, all-in-one boiler water treatment based on organic tannin with built in alkalinity booster. ACUTHERM 3301 is an excellent corrosion and scale inhibitor scientifically formulated using hydrolysable tannin as an …Get Price

Discount
7X24 Online