Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Modified MRAC for Controlling Water Level of Boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Modified MRAC for Controlling Water Level of Boiler
  • Supply Capacity : 10 units/month :Modified MRAC for Controlling Water Level of Boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Boiler Level Control Using Labview - ijcaonline.org

    A boiler system is an integral component of a sugar plant and control of water level in the drum of the boiler is a critical operational consideration. Nowadays, instead of conventional control techniques, modern control techniques have been implemented for a lot of industrial models practically or theoretically.Get Price

  • Modified Hot Well Level Control System using Basic Logic …

    modified hot well level control system using basic logic gates. The control of water level in the hot well is a critical operational consideration. Now a days, modern control techniques using logic gates have been implemented for a lot of industrial models In the boiler, the chemical energy is converted in to the thermalGet Price

  • STEAM DRUM WATER LEVEL MEASUREMENT

    Boiler steam drum water level is one of the most important power plant parameters to both measure and control. Control of the proper water level in the boiler is critical for safe operation of the boiler. If the level is too low, boiler tubes will be damaged by overheating. If theGet Price

  • Indoor Coal Boilers Products | Alternate Heating Systems

    Every ASME Accredited water jacket has been pressure tested to 60 PSI and comes with a 30 PSI release valve. Low Water Cutoff. A Low Water Cutoff senses the water level in the boiler's vessel and will close the unit down if the water level falls to a dangerous level. It is available in both manual and automatic reset.Get Price

  • Model Reference Adaptive Control for Deaerator Pressure

    Methods of Detecting Water Level in Steam Boilers | Spirax Get Price

  • ‪Bhagsen J. Parvat‬ - ‪Google Scholar‬

    Methods of Detecting Water Level in Steam Boilers | Spirax Get Price

  • Boiler Drum Level Control - Chemical Engineering World

    Nov 03, 2020 · If the water level gets too high then it may be possible that such amounts of liquid enter are transported downstream that they damage the equipments. Usually it is a standard to maintain the boiler drum level at 50% during operation. The designs for boiler drum level control are referred to as single element, two element and three element control.Get Price

  • Ústav informatizácie, automatizácie a matematiky

    Fan Zhang – Xiao Wu – Jiong Shen: Extended state observer based fuzzy model predictive control for ultra-supercritical boiler-turbine unit. Applied Thermal Engineering, zv. 118, str. 90 - 100, 2017. Emre ÖZKOP – İsmail Hakkı ALTAŞ: Performance of PSO Based Classical and Intelligent Controllers for Water Level Control of a Steam Generator.Get Price

  • Technical Manual Operation & Maintenance Boiler Model

    The water level control system consists of a probe system internal to the boiler shell that monitors the water level and automatically activates the feedwater pump system as needed. There are also 2 low water level probes to shut the burner off in the event of a low water condition. Mounted on the front of the boiler is a water level gauge Get Price

  • Ketel Uap (Boiler) di Pabrik Kelapa Sawit ~ Industri Sawit

    Dec 07, 2012 · Tabel.1. Komposisi Bahan Bakar. Ketel uap yang digunakan di pabrik kelapa sawit biasanya adalah ketel uap dengan kapasitas uap 20.000 Kg uap/jam dan dengan tekanan 20 kg/cm2. dimana dibutuhkan 2 unit boiler untuk pabrik kelapa sawit dengan kapasitas olah 45 ton TBS/jam. Sebagian besar ketel uap yang digunakan pada pabrik kelapa sawit adalah Get Price

  • Why Three Element method for Boiler Drum Level Control

    Feb 20, 2021 · The term "3-element control" refers to the number of process variables (PVs) that are measured to effect control of the boiler feedwater control valve. TheseGet Price

  • Feedwater Level Control of Boiler Steam Drum using IMC and

    The full scale mathematical model of a drum boiler for water level control is established by H. Kim and S.Choi [1], which includes the water level dynamics in the drum-riser-down comer loop.The mathematical model of Steam Drum is extracted from Juhua Wang and QingjinMeng, [2] which involves the state space dynamics of steam DrumGet Price

  • Section 23 09 11 - INSTRUMENTATION AND CONTROL FOR …

    The boiler and burner control, monitoring, data gathering, instrumentation and associated systems specified in this section shall be provided by one company that has been in business at least three years engineering, designing and servicing industrial and institutional boiler control and instrumentation systems similar to those specified herein, as a primary business.Get Price

  • Fuzzy Adapting PID Based Boiler Drum Water Level Controller

    thermal power plant controls. Boiler water level control system includes steam drum water level, steam flow and water supply. The control objective is to control the water level of boiler drum. Fuzzy Adaptive PID controller is designed for controlling the …Get Price

  • Methods of Detecting Water Level in Steam Boilers | Spirax

    Methods of Detecting Water Level in Steam Boilers. On a steam raising boiler there are three clear applications for level monitoring devices: Level control - To ensure that the right amount of water is added to the boiler at the right time. Low water alarm - For safe boiler operation, the low water alarm ensures that the combustion of fuel does Get Price

  • BOILER MONITORING - Autoflame

    The DTI can collect information from up to 10 of each of the following Autoflame products: Mk7 MM Controller, Mini Mk8 MM Controller, Mini Mk7 MM Controller, or any combination to a total of 10 unitsAutoflame Exhaust Gas Analyser, either used in conjunction with an MM Controller for trim, or linked directly to the DTI for monitoring purposes only.Get Price

  • US4662390A - Water level controller for a boiler - Google

    A water level controller for a boiler has electrical probe means (capacitive or conductive) to be arranged in the boiler to detect electrically the water level therein. An oscillator circuit generates an oscillator signal which first and second circuit means receive. When a capacitance probe is used, the first circuit means has a variable gain amplifier in which the gain is determined by Get Price

  • Simulation of control of water level in boiler drum

    Water Levels in Steam Boilers | Spirax SarcoGet Price

  • Solved TUTORIAL QUESTIONS a) Draw the logic system for

    The boiler is switched "ON" when the air temperature falls below a predetermined level OR when the water temperature falls below a preset level. b) The boiler control circuit in the above problem is to be modified to provide safety functions. The boiler is to switch "OFF" if the water temperature exceeds a prescribed maximum. A second water Get Price

  • Section 23 50 11 - BOILER PLANT MECHANICAL EQUIPMENT

    Control station shall indicate actual water level, soft water and emergency city water level set points and valve positions. Provide same indicating and control features on computer workstation specified in Section 23 09 11, INSTRUMENTATION AND CONTROL FOR BOILER PLANT.Get Price

  • PT. Persada Dinamika Jaya

    SDM Berpengalaman di Teknik Konstruksi dan Boiler. Kontraktor Pembangunan Pabrik Kelapa Sawit, Melayani sektor Industri Kelapa Sawit baik pembangunan dan juga maintenance, kami juga terus melayani bidang industri turunan/hilir dari Minyak Kelapa Sawit.Get Price

  • Modified MRAC for Controlling Water Level of Boiler …

    Request PDF | On Dec 1, 2015, Narendra N. Parekar and others published Modified MRAC for Controlling Water Level of Boiler System | Find, read and …Get Price

  • (PDF) Controlling drum level of a utility boiler during

    Controlling drum level of a utility boiler during Boiler Feed Pump runback using related rate concept Dr. Pradip Chanda*, Dr.P.M.V. Subbarao IIT Delhi INDIA Abstract - Steam boiler provides appropriate quality and generator where boiler is divided into lumped-parameter quantity of steam to the turbine for power generation.Get Price

  • IJCA Contents Orig – NADIA

    Jul 08, 2020 · Improvement Direct Power Control on PWM using Modified Deadbeat Controller, Mahdi Zarif, Afsaneh Morvari and Masoud Goharimanesh (pp. 77 -86). High-Precision Indoor Flight Path Tracking using UWB Sensor in a Thermal Power Plant Boiler, In-Kyum Kim, Won-Hyuck Choi and Min-Seok Jie (pp. 87-96).Get Price

  • Control Systems and PID | PDF | Control System | Feedback

    Design of MRAC using modified MIT rule for a second order system.pdf. 6_Tuning and Control Schemes.ppt. Lect 7 The Control System.docx. Download now. Jump to Page . You are on page 1 of 25. Example for such a system is boiler water level control. Explain two step control action, Get Price

  • Gas-Fired Condensing Hot Water Boiler

    Gas-Fired Condensing Hot Water Boiler • Fully modulating (5:1) 20- • Cast Aluminum sectional boiler 8.2.5 Temperature control 29 . 8.2.6 Low water level protection 29 . The boiler must not be modified or fitted with non OEM spare parts without the …Get Price

  • Boiler Drum Level Control Using US1000 | Yokogawa America

    The US1000-11 Dual Loop Digital Indicating Controller can easily be implemented as a three element boiler drum level/feed water controller. Steam drum level control is necessary to add makeup water as steam is delivered into the header pipe. The level measurement and feed water flow input are the process variables (PV) for a cascade control Get Price

  • Feedwater Level Control of Boiler Steam Drum using IMC and

    Jun 22, 2015 · The primary requirements of a boiler are to contain the water safely and the steam must be delivered in desired condition (as regard its pressure, temperature, quality and required rate.). For providing tight water level control of boiler steam drum, there are three types of control strategies are mainly used.Get Price

  • Control of power boilers - Consulting-Specifying Engineer

    Sep 21, 2018 · Boiler controls. All boilers require control of three basic elements to operate safely and efficiently. The three elements are water flow, airflow, and fuel flow. For steam boilers, water flow is used to maintain the drum level. Because the tubes are the part of the boiler used to transfer heat from the flue gases to the water, they are exposed Get Price

  • Sugar_Mill_Control.pdf | Boiler | Process Control

    BOILER SECTION. 2.1 DRUM LEVEL CONTROL The existing boilers are having cascade controllers for 3 element drum level control. However, when steam demand of process is suddenly increased, steam pressure falls and due to swelling phenomenon of water, water level in …Get Price

Discount
7X24 Online