Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Where do I connect my new T-Stat in my Weil Mclain boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Where do I connect my new T-Stat in my Weil Mclain boiler
  • Supply Capacity : 10 units/month :Where do I connect my new T-Stat in my Weil Mclain boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Weil Mclain Boiler Thermostat Wiring - schematron.org

    Oct 24, 2018 · User manuals, Weil-mclain Boiler Operating guides and Service manuals. I have Weil-McLain gas boiler for hot water heat and going to install WiFi thermostat that requires common 24V 'C' wire. I do have a free wire in the cable but cannot figure out where should I connect it on the boiler, there's no any terminal, marked as 'C', 'common' or Get Price

  • Weil Mclain Boiler Thermostat Wiring

    Mar 5, My furnace is a Weil McLain CGi Series 2 furna Do I connect these terminals to the CGi boiler's thermostat connection, or add an Acquastat. Oct 25, I am installing a new boiler in my house, a Weil CGA gas boiler. Part of this, of course, is wiring up my wall thermostat.Get Price

  • Thermostat Wiring / Boiler Inquiry - Heating Help: The Wall

    There is only so much troubleshooting you can do without voltage meter and some know how. One easy test is to jumper (or just touch together) the wires going to RH and W on the t-stat. If the boiler fires, you have a t-stat issue. If this boiler does …Get Price

  • Boiler Wiring (Weil CGa, Tekmar 256, Taco SR501, and T-Stat)

    Nov 28, 2008 · I just looked up the Tekmar 256 and it's an outdoor reset. I can't help much with that. What I do see is the Tekmar boiler taps will tie to the thermostat circuit on the boiler. You'll need to supply 24 VAC to the Tekmar, maybe that can be tapped from the R and C terminals on the boiler. Make sure you aren't overloading that transformer.Get Price

  • Boiler cutting out before CH temp reached - DIYnot Forums

    Sep 03, 2019 · Depends on your boiler. But with older boilers, the boiler thermostat controls the temperature of the water leaving the boiler, and will turn the burner 'on' and 'off' to maintain the selected temperature. Despite it's name, the one thing a boiler shouldn't do is boil the water.Get Price

  • Install C wire for Nest E on Weil McLein PEG steam boiler

    All you need to do is connect your C wire to the ground on the boiler. I've had a C wire on my by EG series since 2012. There's no need for a separate transformer. Single pipe quasi-vapor system. Typical operating pressure 0.14 - 0.43 oz. EcoSteam ES …Get Price

  • Aquastats: Setting & Wiring Heating System Boiler Aquastat

    I have a Weil / McLain boiler with 2 zones using a what appears to be a 8182D Aquastat controller. I rewired things so that the thermostats control only the circulator on each zone respectively. Since doing so the boiler seems to keep the temp at the low setting (140F) only and does not ever reach the hi setting of 180F.Get Price

  • Weil Mclain Boiler Wiring Diagram - justussocializing.org

    Dec 16, 2021 · Weil Mclain Boiler Wiring Diagram– One of the most hard automotive repair tasks that a mechanic or repair shop can assume is the wiring, or rewiring of a car's electrical system.The difficulty truly is that every car is different. similar to bothersome to remove, replace or repair the wiring in an automobile, having an accurate and detailed weil mclain boiler wiring …Get Price

  • Indirect Hot Water Tank - DoItYourself.com Community Forums

    Apr 10, 2016 · Boilers - Home Heating Steam and Hot Water Systems - Indirect Hot Water Tank - After 14 years, my indirect water heater has finally called it quits. I am having a professional install a new one in a day or so. It is a 50 gallon Bradford Indirect Tank. I always thought the water inside the tank circulated by the pumpGet Price

  • How do you adjust the temperature on a Weil McLain boiler?

    Jan 29, 2020 · How to Clean a Weil Mclain Boiler. Turn off the Weil Mclain boiler and turn off the gas line to the boiler, if needed. Wipe down the exterior of the boiler with a damp cloth to remove any dust. Vacuum around the boiler to keep dust and lint from clogging the system.Get Price

  • I have a Weil McLain, hot water boiler and want to use a

    Sep 05, 2009 · I have a Weil McLain, hot water boiler and want to use a programmable thermostat. Which thermostat would work best with - Answered by a verified HVAC Technician I installed a new weil-Mclain sgo 3 stem boiler and I want how to connect The old one was replaced by a new boiler. The new Weil-McLain Gold Oil Unit was installed January 2005.Get Price

  • FAQs | Weil-McLain Boilers & Products

    Weil-McLain ® does not employ heating technicians who come out to repair your boiler, nor do we have factory-authorized servicers. We rely upon independent heating professionals in your area to install, maintain and troubleshoot Weil-McLain products. Please contact a heating professional in your area.Get Price

  • 6 Best Boiler Thermostats - Smart, WiFi Thermostats For

    Dec 14, 2021 · As I noted above, there are different types of boiler systems like gas-fired boiler, steam boiler, and fuel oil-based boiler. Out of these 3 types, gas-fired boiler is the most common one in USA, just like the central furnace-based heating systems.You may find steam boilers in some older home constructions, but they are being replaced eventually.Get Price

  • How to connect thermostat C wire to Weil-McLain CGa boiler

    According to the CGa-010 wiring diagram, you'll want to connect the C wire for the thermostat to the terminal pointed to in this image. Notice the transformer is circled in red. The location where the transformer wiring terminates is circled in orange. The "common" side of the transformers secondary is pointed to by a large blue arrow.Get Price

  • TSTAT/CIRC Light Flashing on My Weil-McLain Boiler

    Apr 14, 2020 · The TSTAT/CIRC light on my Weil-McLain boiler started flashing recently. In troubleshooting, I found it was from when I had one of my two thermostats on. If I turn that thermostat off the light stops flashing and the boiler operates normally for the other thermostat. I've tried swapping the thermostats, using the working good one and same results.Get Price

  • How to add a C-wire to Weil McLain Boiler – iTecTec

    My existing control wire utilized an Rh and W on the thermostat, but utilized the Y and G terminals on the boiler itself. The installation manuals indicate I need to connect a new C-Wire from the C terminal from the boiler to their c terminal on the thermostat and reconnect the other wires as is, but that doesn't work.Get Price

  • Help with connecting Honeywell Wifi thermostat to Weil

    My previous battery operated thermostat has no 'C wire' but has two unused wires which terminate next to but not connected to our Weil McLain boiler. In the boiler there is no traditional screw type connection but rather a plastic plug with many wires coming out the back, the front of which attaches to the T-STAT position on the control board Get Price

  • Thermostat Wiring / Boiler Inquiry - Heating Help: The Wall

    There is only so much troubleshooting you can do without voltage meter and some know how. One easy test is to jumper (or just touch together) the wires going to RH and W on the t-stat. If the boiler fires, you have a t-stat issue. If this boiler does …Get Price

  • How to Troubleshoot a Weil McLain Boiler | Hunker

    Weil McLain sells a variety of boilers for residential use. Both their gas- and oil-fired boilers are designed to be easy to use and provide consistent heat for years to come. To extend the life of your Weil McLain boiler, read its owner's manual thoroughly and abide by …Get Price

  • Boiler Manual • Installation - Weil-McLain

    Therefore, Weil-McLain equipment contaminated with saltwater or polluted water will no longer be covered under warranty and should be replaced. Electrical Damage — If any electrical component or wir-ing came into contact with water, or was suspected to have come into contact with water, replace the boiler with a new Weil-McLain boiler. water.Get Price

  • WARNING CAUTION WARNING - Weil-McLain

    boiler supplies adequate temperature to heat the indirect tank (see page 7). ZONE/ INDIRECT SWITCH POSITION ZONE/ INDIRECT SWITCH POSITION Connect thermostat or end switch from zone relay or multi-zone panel to T-T.Connect circulator to C2-C1.Move Zone/Indirect Switch up to Z. Connect end switch from circulator relay or multi-zone panel to ZC-ZR.Get Price

  • Weil-McLain CGM 4 boiler does not start | DIY Home

    Jan 31, 2016 · The ignition system indicates it is supposed to retry every 5 minutes if the burner does not light but I have not observed this so wonder if it never gets to this step. The components: Boiler - Weil McLain CGM-4-PL Series 7. Gas Valve - Honeywell VR8204A2001. Transformer - White Rodgers S84A-66.Get Price

  • Ecobee 4 Install Help - T&T Aquastat w/ Taco Zone Valves

    I've been reading up on this subreddit all day, hoping the Ecobee experts can assist me in another install thread! The quick summary, I moved in to a new house that has: Weil-Mclain oil boiler. Honeywell T&T aquastat. 4 heating zones controlled with Taco 571 Zone valves. A "zone" for the indirect water heater with another Taco Zone ValveGet Price

  • How to add a C-wire to Weil McLain Boiler – iTecTec

    My existing control wire utilized an Rh and W on the thermostat, but utilized the Y and G terminals on the boiler itself. The installation manuals indicate I need to connect a new C-Wire from the C terminal from the boiler to their c terminal on the thermostat and reconnect the other wires as is, but that doesn't work.Get Price

  • How to Troubleshoot a Weil McLain Boiler | Hunker

    Weil McLain sells a variety of boilers for residential use. Both their gas- and oil-fired boilers are designed to be easy to use and provide consistent heat for years to come. To extend the life of your Weil McLain boiler, read its owner's manual thoroughly and abide by …Get Price

  • TACO ZONE CONTROLS WIRING GUIDE - TACO - HVAC

    power t stat typical wiring (cold start) t ac power tor r w t t 24 c com n/o n/c n/c n/o 3 6 5 to: tt on boiler sr501 1 zone switching relay power * t stat * alternative wiring (24 vac powered input signal) h n remove jumper. do not connect power to n and h terminals. 24 vac signal stat light will go on and off with 24 vac signal.Get Price

  • Help with connecting Honeywell Wifi thermostat to Weil

    My previous battery operated thermostat has no 'C wire' but has two unused wires which terminate next to but not connected to our Weil McLain boiler. In the boiler there is no traditional screw type connection but rather a plastic plug with many wires coming out the back, the front of which attaches to the T-STAT position on the control board Get Price

  • Trying to connect new wires to a Weil-McLain Cga boiler

    My son bought a new Weil-McLain GOLD CGa gas fired water boiler (UR8200C1074) for his new shop. The boiler came set up for natural gas. Since natural gas isn't available in his location, it also came … read moreGet Price

  • GOLD CGt - Weil-McLain

    • If new boiler will replace existing boiler, check for and correct system problems, such as: 1. System leaks causing oxygen corrosion or section cracks from hard water deposits. . Incorrectly-sized expansion tank. of antifreeze in boilerwater causing system and to freeze and leak. Before placing boiler in boiler room, mount the ambient tempera-Get Price

  • Steam Boiler to tstat wiring — Heating Help: The Wall

    Y at the boiler to R at the stat, only cut the R,Rc jumper if you have A/C. W at the boiler to W at the stat. C at the boiler to C at the stat. Done. You will have constant 24v at the stat unless the circuit opens due to a fault on the damper or LWCO.Get Price

Discount
7X24 Online