Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.
We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.
The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence
Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
What Is Firing Rate Of A Boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Each boiler has a boiler master, which is an A/M/Bias station that handles the firing rate for that boiler. In AUTO, the boiler master receives the plant master output, biases it, and sends that % to the fuel and air flow controllers. In MANUAL, the boiler master output is adjusted by the operator.Get Price
Jun 15, 1994 · During the test, the unit consumed coal at an average rate of 234.2 ton/hr. Unit One is a pulverized coal-fired, dry bottom boiler with an opposed firing configuration. Low NOx burners are used to control NOx emissions. Normal operating temperature in the combustion zone is approximately 2,000 - 3,000 degF.Get Price
Feb 23, 2018 · The benefits of boiler modulation are threefold; it reduces cycle losses, it reduces the wear on the components, and it can (but not necessarily as shown later in this article) result in higher thermal efficiencies. But aside from the benefits, what are the impacts of firing rate modulation on gas firedGet Price
In manual mode, Boiler B is said to provide a base load of steam production. With the firing rate of Boiler B set manually from the Boiler Master, it is unresponsive to firing demand signal variations from the Plant Master. We then would have two swing boilers (Boiler A and Boiler C) and one base loaded boiler (Boiler B).Get Price
Boiler Turndown is a comparison of the Maximum Input of the boiler compared to the Minimum Input that the boiler will properly operate. To calculate your actual Turndown you need to know what your actual input is at Maximum and Minimum firing rates.Get Price
Feb 24, 2012 · Pulverized Fuel Firing. For obtaining the most calorific value of coal, the coal is pulverised in fine powder and then mixed with sufficient air. The mixture of coal powder and the air is fired in the steam boiler furnace to achieve most efficient combustion process. Pulverized fuel firing is most modern and efficient method of boiler firing.Get Price
The burner will modulate between low and high firing rates depending on the steam pressure inside the boiler and where the modulation control is set. If the boiler setpoint is 80 PSI and the pressure in the boiler is 81 PSI, the modulation control should be sending a signal to the burner to drive to a lower firing rate if it is not already in Get Price
Apr 27, 2018 · The firing-rate control will drive the burner to low-fire position at 2 psig and will stay at low fire until the boiler pressure reaches 4 psig, where the operating control will shut off the burner or increase the boiler firing rate if the steam pressure drops 1 psig lower. Differential.Get Price
typical Firetube through the Firing Range typical firetube through the Firing Range 85 85 83 83 Fuel % Efficiency % Efficiency 81 81 Savings 79 79 77 77 C-B Classic Integral Firetube CBEX Elite Typical Firetube Typical boiler firing range Typical Firetube 75 75 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 % Firing Rate % Firing Rate Recognizing this, in 1990, …Get Price
Fire-tube boilers usually have a comparatively low rate of steam production, but high steam storage capacity. Fire-tube boilers mostly burn solid fuels, but are readily adaptable to those of the liquid or gas variety. Fire-tube boilers may also be …Get Price
Where the firing rate is defined as between 0 and +1, P Hi is the upper pressure setpoint for the control of the boiler, and P Lo is the lower pressure setpoint for the boiler. This arrangement will be graphically disclosed in Fig. 2, but generally indicates that at a low pressure in a typical boiler, the firing rate is very high.Get Price
In general, as the firing rate of a boiler decreases, there is a corresponding increase in excess air requirements, leading to lower efficiencies at the lower end of the firing range. Boiler manufacturers usually provide boiler efficiency curves over several firing rates (e.g. , 75%, 50%, 25%) based on laboratory results.Get Price
The application of the 'from and at' rating graph (Figure 3.5.1) is shown in Example 3.5.1, as well as a demonstration of how the values are determined. Example 3.5.1. A boiler has a 'from and at' rating of 2 000 kg/h and operates at 15 bar g. The feedwater temperature is 68°C. The use of Equation 3.5.1 will determine a factor to Get Price
boiler or process heater firing solid or liquid fuels that is selected to conduct a stack test. You will need to conduct one fuel sample (comprised of three composite samples, each individually analyzed) of the fuel used during the stack test (one composite sample per …Get Price
Oct 12, 2015 · The boiler is carried out firing from cold condition to normal working pressure condition very slowly to avoid thermal stress. Check the boiler blow down valve in close position. Shut the main steam stop v/v. Open the air vent cocks. Open the feed check valve and pumping up to ¼ of gauge glass level.Get Price
Jan 13, 2015 · Each boiler has a boiler master, which is an A/M/bias station that handles the firing rate for that boiler. In AUTO, the boiler master receives the plant master output, biases it, and sends that percentage to the fuel and airflow controllers. In MANUAL, the boiler master output is adjusted by the operator.Get Price
Apr 02, 2013 · The thumb rule for coal firing is, the fresh coal received must reach coal bunkers first for firing in the boiler. The heat rate by parameters deviation method is the best method for controlling the process, understanding the maintenance required for the equipment on day to day basis and to achieve best performance from the plant. This method Get Price
The energy loss can be reduced by using a high turndown burner (10:1), which keeps the boiler on even at low firing rates. Every time the boiler cycles off, before it comes back on, it must go through a specific start-up sequence for safety assurance. It takes between one to two minutes to get the boiler back on line. If there is a sudden load Get Price
Oil Boilers | Prices and Installation Costs 2021 | ModernizeGet Price
With the advanced CBEX firetube boiler's 10:1 turndown combined with unprecedented high efficiencies across the turndown range, operators will recognize tremendous fuel savings while operating below the 60% firing rate and throughout the boilers entire firing range. *10:1 turndown available on CBEX models larger than 200 BHP.Get Price
Must be limited to low fire until sufficient warming so the boiler doesn't warm up too fast on high fire and cause thermal expansion and excessive stress on the boiler. Modulating firing rate control Provides the highest efficiency and closes set point adherence of …Get Price
Jan 24, 2021 · Simply by bringing down the energy input and reducing the firing rates needed for the boiler output. Superheater:-The main purpose of the superheater is to increase the temperature of saturated steam without raising its pressure. The fire-tube boiler utilizes two types of heat (sensible heat and latent heat) to convert water into steam.Get Price
Purchasing Energy-Efficient Large Commercial Boilers Get Price
Dec 17, 2020 · A modulating boiler will run on low fire to provide the small amount of heat needed, instead of firing to full capacity. Modulating boilers are also great in small homes for supplying domestic hot water through the use of an indirect fired water heater, like the U.S. Boiler Company Alliance .Get Price
The Boiler Management Control System shall incorporate a microprocessor based design and provide the operating control function of the boiler system and modulation control of fuel and combustion air as well as the firing rate motor to meet system demand. The control system shall be provided by Fireye Inc. or written approved equal.Get Price
Firing – Aside from the standpoint of economy, maintain the fire as uniformly as possible to avoid an excessive rate of combustion, undesirable variations in temperature and possible explosions. The destructive force in a boiler explosion is caused by the instant release of energy stored in the water as heat. Water gaugesGet Price
Jun 18, 2014 · For instance, if a boiler has an Input of 200,000 BTUH and a Gross Output of 160,000 BTUH, that boiler would be running at 80% combustion efficiency. It's not hard to figure this out. Just divide the big number into the little number and then multiply the result by 100 to get a percentage. And this brings us to Net Output.Get Price
gases which are emitted by the boiler is a function of the firing rate and associated theoretical air requirements and excess air used in the combustion process. The more excess air used, the larger the volume of exhaust gases for a given firing rate and the lower the exit gas temperature. The volume rate of flow of the exhaust gas canGet Price
Firing rate valve - valve equipped with a modulating motor controlled by boiler pressure (steam) or temperature (hot water) and regulates the amount of fuel to the burner and through linkages, controls the air damper (like the cruise control on a car), …Get Price
Why are you buying a new boiler?Get Price