Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
Steam Boiler Condensate and Feed Water System -
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
A Feedwater Treatment and Condensate Handling System is required with any boiler and steam generation system to properly prepare the inlet feedwater. It should consist of the feedwater (or condensate) receiver, water softener system, chemical injection system and blowdown tank with a cooling water valve.Get Price
Steam that has been condensed back into water by either raising its pressure or lowering its temperature. Not to be confused with demineralized, de-ionized, make up, or softened water. When the condensate enters the boiler feed pump additional chemicals are added and the product is now called boiler feed water.Get Price
The Parker Return System are standardly recommended with high pressure steam boilers to supply water with a boiler feed pump that operates on demand from the boiler water level control. The tank provides storage for water make-up and return condensate from the system when available with the advantage of preheated water.Get Price
In steam boiler systems, it is important that sufficient amount of condensate is present with good quality. With the help of Conductivity-Control, continuous conductivity monitoring and targeted discharge control of contaminated condensates are carried out.Get Price
Balance condensate flow between multiple de-aerators to increase overall system capacity and operating flexibility; Insure reliable supply of boiler feed water while maximizing return of condensate to save energy and reduce chemical treatment costs; Identify and quantify leaks in the system; Steam and Condensate System Study CapabilitiesGet Price
Apr 18, 2017 · The condensate pump will feed water into the boiler whether the boiler needs any or not. This was acceptable with the old, large boilers because the water level was not as crucial as it is for the newer ones. If the system required make-up water, water was fed directly into the boiler through a float valve located on the boiler.Get Price
Condensate and Feedwater Systems. For boilers up to 200 hp. Horizontal and vertical orientations. Turbine and centrifugal pumps available. Single pump and multi-pump configurations. Constructed of heavy 10 gauge steel. Stainless steel optional. Download vertical and horizontal systems brochure. Download dimensions and connections for vertical Get Price
Waste Heat Boilers Low Pressure Systems Medium to High Pressure Systems Process applications HRSG. D and A type boilers Steam separation equipment - drum furniture Cyclone separators Demister pads Condensate 0 10 15 0 50 Feed water 1 105 182.5 3 Basic Boiler Calculations. Boiler Water Best Practises.Get Price
Jan 06, 2017 · Deaerators for boiler feed water offer a long list of benefits to virtually any steam-plant system. Some of the key benefits include: Removal of carbon dioxide (CO2) and oxygen (O2) from feed water to reduce corrosion. Serves as a surge collection source for condensate return from the process. Increases efficiency from preheating feed water.Get Price
Condensate Water Treatment to Prevent Steam Boiler Pipes Get Price
May 02, 2000 · the system requires energy to raise its temperature to turn it to steam. As sentinels of the heart of dry kiln plants, boiler operators have control over two basic aspects of the chemical program; blow down and chemical feed.Get Price
In steam boiler systems, it is important that sufficient amount of condensate is present with good quality. With the help of Conductivity-Control, continuous conductivity monitoring and targeted discharge control of contaminated condensates are carried out.Get Price
Jan 18, 2021 · Lag time is the amount of time it takes from when the boiler starts sending steam into the system until the condensate is flowing back into the boiler feed receiver. When a boiler starts steaming in a heating system, the steam has a lot of jobs. It must push the air out of the system so the steam can get in and that takes time.Get Price
Boiler Systems Chapter 3 7.0 Chemical Treatment 7.1 OVERVIEW This section deals with specific chemical treatments. Type, purpose, and application are all discussed. The treatments are divided along the lines of preboiler and condensate systems, and …Get Price
Many feedwater systems fail prematurely due to the corrosive effects of condensate and oxygenated make-up water. If the feedwater system experiences significant levels of make-up and steam is used for feedwater preheat in the feedwater system, a standard "carbon steel" vessel may fail prematurely. The corrosion resistant options available areGet Price
Oct 31, 2021 · If you have a steam boiler, your boiler system produces steam. Steam leaves the boiler through piping to transfer heat to something; usually a heat exchanger or steam jacket. When the steam condenses in the pipe it is called condensate. This condensate water has very little impurities in it. In fact, condensate is practically pure, clean Get Price
Condensate return. As steam is generated, the water within the boiler evaporates and is replaced by pumping feedwater into the boiler. As the steam passes around the system to the various items of steam-using plant, it changes state back to condensate, which is, essentially, very good quality hot water.Get Price
Apr 18, 2017 · The condensate pump will feed water into the boiler whether the boiler needs any or not. This was acceptable with the old, large boilers because the water level was not as crucial as it is for the newer ones. If the system required make-up water, water was fed directly into the boiler through a float valve located on the boiler.Get Price
Sep 17, 2021 · When you need to generate steam, it can be frustrating to have a simple process impeded by outside variables. These impurities can clog strainers and valves, cause pipe or tube failures or form sludge build-up and corrosion within the boiler system. Each boiler system has its own limit of Total Dissolved Solids (TDS) in the feedwater and the Get Price
Jul 16, 2009 · 2. To prevent corrosion in the boiler feed system by maintaining the boiler water's alkaline condition. 3. To remove dissolved gases such as oxygen from water. 4. To control sludge formation, thus preventing carry over into the system. 5. To determine the amount of impurities and thereby determining the amount of treatment required. 6.Get Price
Sep 26, 2016 · For industrial companies using a boiler for its facility, some type of boiler feed water treatment system is usually necessary to ensure an efficient process and quality steam generation. The most appropriate boiler feed water treatment system will help the facility avoid costly plant downtime, expensive maintenance fees, and boiler failure as a result of scaling, …Get Price
Feedwater Systems | Rite Boilers These systems typically receive waterGet Price
___ feedwater regulators are found on package fire-tube or watertube boilers where feedwater pumps run either intermittently or consistantly Float A 3-element feedwater regulator measures the steam flow from the boiler.. the ___ into the boiler, and the water levelGet Price
Why a RO System is necessary for Boiler Feed Water Pretreatment. Advantages: - Reduce fuel costs through lower heat loss and increased boiler cycles. Reducing the total dissolved solids (TDS) in the RO product water can increase the boiler's cycles of concentration. The boiler will also have a cleaner heat transfer surface and is more efficient.Get Price
Many feedwater systems fail prematurely due to the corrosive effects of condensate and oxygenated make-up water. If the feedwater system experiences significant levels of make-up and steam is used for feedwater preheat in the feedwater system, a standard "carbon steel" vessel may fail prematurely. The corrosion resistant options available areGet Price
Roth steam condensate pump return stations eliminate boiler system problems and continue to provide the efficient return of hot condensate to the boiler or feedwater system. Roth steam condensate pump return stations are supplied with reliable pumps that are designed to handle hotter water and develop higher pressures at lower speeds.Get Price
Chemical treatment of feedwater is introduced through by-pass feeders in the line between the pump and boiler or by means of proportioning pumps directly to the boilers so that feedwater chemicals do not pass through the pump. Collect and return hot steam condensate to the boiler or boiler feed unit in low-pressure steam heating systems.Get Price
It is a necessity for high-pressure, high-temperature boilers that operate at pressures greater than 2,400 PSIA. Above the 2,400 PSIA threshold, contaminants in the boiler feed water (sodium, chloride, iron, calcium, silica, etc.) will carry over in the vapor of the steam produced and affect downstream processes.Get Price
Product Overview. Provide safe, trouble-free delivery of water and condensate return for boilers. Feedwater systems are completely assembled with a tank, stand, pump, motor starter, float valve, shut-off valve, and gauge glass assembly. Optional steam preheats are also availablecompletely assembled and engineered by Fulton for ease of mind.Get Price
Boiler Feed & Condensate Handling. ESP-Systemwize. Bell & Gossett's Domestic Pump Series – the most complete line of products needed for steam systems. Boiler Feed & …Get Price