Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

water analysis amount of boiler feedwater per hour details

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :water analysis amount of boiler feedwater per hour details
  • Supply Capacity : 10 units/month :water analysis amount of boiler feedwater per hour details
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • (PDF) ASME Standar | Carlos Mesa - Academia.edu

    CONSENSUS ON OPERATING PRACTICES FOR THE CONTROL OF FEEDWATER AND BOILER WATER CHEMISTRY IN MODERN INDUSTRIAL BOILERS prepared by the FEEDWATER QUALITY TASK GROUP for the INDUSTRIAL SUBCOMMITTEE OF THE ASME RESEARCH AND TECHNOLOGY COMMITTEE ON WATER AND STEAM IN THERMAL POWER SYSTEMS THE …Get Price

  • boiler cpacity in kg steam per hour water tube

    Water Tube Boilers - Chipkin Automation Systems. capacity also called power of a boiler. It is defined as the amount of water evaporated or steam produced in kg per hour. It may also be expressed in kg per kg of fuel burnt or kg/hr/m2 of heating surface. 2.1.1 Boiler Classifications Boilers are classified by theirGet Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    As expected the longer the boiler stands-by the larger are the fuel savings. Thus a boiler operating for 12 hours, firing typically for about one-third of a cycle has a fuel saving of 5.5% compared to 1.7% for 24 hours operation. Decreasing the number of firing cycles per hour (n) increases the fuel saving, Figure 6, but onlyGet Price

  • Calculating Boiler Chemical Requirements – Water

    Jun 26, 2017 · Assume boiler is operating at 10 cycles of concentration with feedwater at 205 o F. This equates to a dissolved oxygen content of 0.7 ppm or 0.5 cc per liter. Assume a feedwater demand of 500,000 lbs per day. The desired sulfite residual is 30 ppm. 1. For fixation of dissolved oxygen: 0.7 ppm x 10 ppm = 7 ppmGet Price

  • DESIGN GUIDELINE 220020 HIGH PURITY WATER SYSTEMS

    • Daily production in gallons per 24 hour day • Storage tank size (gallons) • Distribution loop flow rate (gpm) and head (ft.) • Indicate that system performance be guaranteed based on the stated feed-water analysis, including temperature. Softeners for boiler water make-up systems shall be duplex demand initiated type.Get Price

  • Guidelines - Atlantic Feedwater Systems, Inc

    For most firetube and commercial water tube boilers convert the horsepower to pounds (#) of steam per hour. Then divide the # per hour of steam by 500 to get the evaporation rate. 2. Calculate the Pump Flow Rate. The flow rate is determined by the amount of water the boiler needs to make steam at full capacity.Get Price

  • A12 Ch4 Feedwater Systems Flashcards | Quizlet

    Differential feed water pressure. b. The most reliable method of checking or testing a low water fuel cutoff is to: A) Lower the water in the boiler to the level where the burner should cut out. B) Blow the float chamber down to see if the burner will cut out. C) Blow down the sight glass to see if the burner goes out.Get Price

  • Determining Softener Size for Boiler Feedwater - Complete

    Oct 10, 2017 · Feedwater Analysis Includes: Industrial Boiler water testing is important to understand the scaling or corrosion potential of the water, to see …Get Price

  • (PDF) Recovery boiler water treatment

    ing only once per shift, some have found out the hard way feedwater and boiler water chemistry. Figure 9 presents. amount of dissolved oxygen (8,000-14,000 ppb) …Get Price

  • Controlling TDS in the Boiler Water | Spirax Sarco

    For raw water, feedwater and condensate the relative density is so near to that of pure water that it cannot be measured satisfactorily using a hydrometer. For boiler water, however, a hydrometer can be used to obtain an approximate measurement of the dissolved solids, since for boiler water each increase of 0.000 1 relative density at 15.5°C Get Price

  • BOILER WATER TREATMENT FUNDAMENTALS - DieselShip

    Sep 03, 2020 · Although water from marine evaporators and boiler condensate return systems is essentially "pure", minute quantities of potentially harmful salts and minerals can be carried by this composition and feed water into the boiler, where they will accrue, ultimately resulting in serious problems in the steam generating unit.Get Price

  • COAL FIRED BOILER -PRINCIPALS - Energy Commission

    To Boiler 171.3 p 245.2 T 515 M 44.15 T 437.6 M Double HP Feed Water Heater Train & Single LP Feed Water Heater Train STEAM PRO 25.0 HRL Limited HRL Technology Pty Ltd. 485 Kefid15 10:02:34 C:AndebIFMEBoiler TrainingTFlowTBP 700 MW Unit, Ver 1.STPGet Price

  • The World's Leading Laboratory Network - Eurofins Scientific

    and the specific properties of the water from which the boiler feed is derived. This is very site specific but we have the testing capability to cover all your requirements. A boiler requires testing of three different water types as shown below: Feedwater Not all feed-water is created equally. Boiler feedwater is sourced from many different Get Price

  • An Introduction to Treatment of Steam Boiler Water

    (British thermal units [BTU] per hour), specifically: 1) one boiler horsepower unit reflects the energy to convert 15.7 kilograms (34.5 pounds) of water to steam from (and at) 100 o C at sea level, which is equivalent to 9.812 kilowatts (33,479 BTU perGet Price

  • INTRODUCTION TO BOILER - 123seminarsonly.com

    Fire tube boilers 2. Water tube boilers 1. Fire tube boilers : Fire-tube boiler is a type of boiler in which hot gases from a fire pass through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam. Get Price

  • Water Treatment Plant Capacity Calculation

    Jan 28, 2017 · So, in this post, I assume demineralized water is used as boiler feed water. Let say we have boiler with capacity of 10 ton/hour. Assume blow down rate is 3%. Demin water demand is = (1+3%) x 10 ton/hour = 10.3 ton/hour. Assuming density of water is 995 kg/m3 so, demin water demand is 10.35 m3/h or 45.57 USgpm. Potable Water DemandGet Price

  • Boiler Water & Feed Water Analysis | Chemistry …

    Boiler Feedwater - an overview | ScienceDirect TopicsGet Price

  • Boiler Auxiliaries

    Return all possible condensate to the boiler plant; this will save on water and chemicals being used to treat the water. 13. Water Pressure. Feedwater is most important to the safe operation of the boiler plant. The hot-water supply temperature should be recorded. Insufficiently heated water can cause scaling or deposits in a boiler. 14.Get Price

  • Steam Calculators: Boiler Calculator - Energy

    Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.Get Price

  • Degasification of Boiler Feed Water with Liqui-Cel

    The feed water flow rate is the amount of water that is added to the boiler. The feed water rate is equal to the boiler capacity + water loss in blow down – condensate return. Feed water flow rate (lb/hr)= [ ] ⎭ ⎬ ⎩ ⎨ ⎧ − ⎥ ÷ ⎦ ⎤ ⎢⎣ ⎡lbs 100 100 Blowdown rate hr boiler capacity ⎫x (100-condensate return) 100 (34 Get Price

  • On-line monitoring of trace amounts of - ScienceDirect

    Sep 30, 1996 · A flow injection analysis (FIA) method for on-line monitoring of trace amounts of copper(II) in steam condensate and boiler feed-water is described. T…Get Price

  • Boiler Safety - Occupational Safety and Health Administration

    is the amount of steam, in pounds per hour (lb/hr), that the safety valve is capable of venting at the rated pressure of the safety valve. piping, and other boiler components. Corrosion is primarily caused by oxygen in the boiler water. Feedwater is treated to remove oxygen by heating and/or chemical treatment. Heating the feedwater removes Get Price

  • Proper sizing of Boiler Feedwater System - P C McKenzie

    A properly sized feedwater system will have a tank adequately sized to feed your boiler and pumps selected to deliver that water at the correct rate and pressure. CALCULATE THE STORAGE TANK NEEDED. In most cases ten minutes of water should be readily available for your boiler. One boiler horsepower = 34.5 lbs/hr of steam (or water) from and at Get Price

  • How much will boiler treatment really cost me? - ChemREADY

    In a process system, another driving factor in cost is returned condensate. The less condensate returned to boiler feedwater tank, the more make-up water a system uses. That will then increase the amount of water that needs to be chemically treated. Systems can range anywhere from 80-90% to 0% down returned condensate.Get Price

  • Boiler Water Analysis - CHEMSCAN

    Boiler Water Analysis. PROJECT REPORT AND DATA SUMMARY. January 19, 1998. Lack of manpower resources has made it increasingly difficult for U.S. Army installations to maintain corrosion and scale control programs for boilers and …Get Price

  • DC Boiler Exam Prep 2015 Flashcards - Quizlet

    1 Boiler Horsepower = x Btu/hr. 33,475 Btu/hr. 1 BHP = x ft² of heating surface (general) 10 ft² heating surface. Volume of water increases by x percent when it flashes to steam. x 1600. Thermal Efficiency (TE) =. = Lbs Steam per hour [Hs - (fwt° -32)] ÷ Units of Fuel per hour x Btu content per unit of fuel.Get Price

  • Georgia-Pacific Palatka Plant Uses Thermal Pinch Analysis

    The primary users of fresh water are the evaporators, the KPMs, and the boiler feedwater system, which together consume more than 50 percent of the total water used at the mill.The mill uses an estimated 18,000 gpm of fresh water. Palatka's No. 2 Kraft Paper Machine ResultsGet Price

  • J. Assignments-Tutorials | 3CH1113 Energy Audit of Process

    Enthalpy of feed water =120 kCal/kg. Annual operating hours of boiler = 7000 hours. In an engineering industry, a heat treatment electrical furnace is consuming 500 kWh per batch. The Energy Manager of the company wanted to convert it to furnace oil firing for cost savings.Get Price

  • Boiler Feedwater - an overview | ScienceDirect Topics

    Boiler Water Analysis. PROJECT REPORT AND DATA SUMMARY. January 19, 1998. Lack of manpower resources has made it increasingly difficult for U.S. Army installations to maintain corrosion and scale control programs for boilers and …Get Price

  • 3 - AR No. 3 - Install VFD of Feed Water Pump

    Based on the boiler's nameplate, at firing rate, the boiler produces 960,000 pounds of steam per day. Analysts assumed the boiler is always operating at firing rate. This means that the pump must provide this volume of liquid water to the boiler in a day. The quantity of time the pump feeds the boiler in a day is theGet Price

Discount
7X24 Online