Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Variable high speed drives for boiler feed pumps

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Variable high speed drives for boiler feed pumps
  • Supply Capacity : 10 units/month :Variable high speed drives for boiler feed pumps
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • (PDF) Power station pump selection: part 2 - ResearchGate

    A.E. Cattaert, E. Pininski, G. Ngcobo and W. van der Westhuizen, Overseas Report on Boiler Feed Pump Redundancy and Voith Vorecon Mechanical Variable Speed Drive, Report No. …Get Price

  • VECO-Drive - Voith

    In February 2020, the first two VECO-Drive units were successfully commissioned and put timeously into commercial operation. Operations have been running smoothly and efficiently at a thermal power plant in Guangzhou, China. The units drive the boiler feed pumps and form part of an energy-saving transformation project.Get Price

  • Operating characteristics of high pressure boiler feed

    1. Modern high-pressure boiler feed pump has two drive modes: one is the water pump driven by steam turbine special, its speed up to 5000 ~ 6000 rpm; the other is by the motor through gear speed after the feed pump driven by variable speed hydraulic coupling, it is as high as 5000 ~ …Get Price

  • Using Variable Frequency Drives with Steam

    Using Variable Frequency Drives with Steam 2 Follow Shipco Pumps® on pumps is an accepted industry standard for most boilers. Based on this formula, the recommended boiler feed pump pumping rate would be 14 GPM. Furthermore, the ASME code dictates that the pump discharge pressure must exceed the boiler relief valve set point by at least 3%.Get Price

  • Energy Audit of Boiler Feed Pump System and Air

    Function of the boiler feed pump is to pump the water from dereator to boiler drum with high pressure. There are six boiler feed pumps in the unit. Four are at running conditions, two at standby condition. Each pump capacity is 4.2MW. Rated efficiency of each pump is 80%. Energy audit techniques for speed control Boiler feed pump are as followsGet Price

  • Variable Speed Fluid Drives - turboresearch.com

    can be used to drive variable speed steam turbines that drive boiler feed pumps. Variable Speed Fluid Drives of the type known as "Hydro-kinetic" are the most important ones for driving larger pumps, and for this reason, they are the focus in this Chapter. This type of fluid drive can be made from a few horsepower to over 40,000 hp.Get Price

  • Variable frequency drive for pumps - Gozuk

    On systems with a high static head, in particular pumping applications for example, boiler feed-water pumps or high lift applications, where the pump must overcome the resistance to lifting the water before any flow starts, the benefits of using …Get Price

  • How do Combi Boilers Work? | Boiler Guide

    Combi boilers are well known for their efficiency. The best combi boilers are at least 93% efficient which means that for every £1 spent on heating your home, only 7p is spent on wasted energy (all gas and oil boilers produce waste energy during operation).Get Price

  • Power | ABB - Drives

    When using variable speed drives, this startup is fully controlled and smooth, preventing an excessive voltage drop in the power plant's supply network. Additionally, mechanical stress on the motor and driven equipment is reduced. High power drives for boiler feed pumps and ID fans - ACS5000. Low to medium power drives for various pump Get Price

  • Power station pumps - Pump Industry Magazine

    Oct 03, 2013 · From the deaerator the feed water is pumped into the boiler by the boiler feed pumps. These pumps are very high pressure multi-stage pumps. They usually have a booster pump to provide suction pressure for the main pump, and they are usually provided with variable speed drives to provide flow control.Get Price

  • Boiler Feed Unit: Pump Minimum Flow | R.L. Deppmann

    Feb 08, 2021 · Model numbers are B&G eSV boiler feed pumps. Design Flow Rate of the Pump. Once you select the required flow of the boiler or boilers being served, do not forget to add the minimum flow which will be a constant bypass. Example: The pump flow rate based on the boiler load is 48 GPM. The pump requires 9 GPM of minimum flow.Get Price

  • Boiler Feed Pump Control Using Variable Frequency Drive

    The fixed speed motor load application such as the boiler feed pump supplies direct AC power. The energy saving is obtained by variable speed drive by using pump affinity laws. By using a Variable Frequency Drive (VFD) to slow down a pump motor speed from to 80% can save 50% of energy. Reducing pump speed not only reduces energyGet Price

  • Energy Conservation Opportunity with a Variable Frequency

    The fixed speed motor load application such as the boiler feed pump supplies direct AC power. The energy saving is obtained by variable speed drive by using pump affinity laws. By using a Variable Frequency Drive (VFD) to slow down a pump …Get Price

  • How does an oil fired boiler work? | Viessmann

    An oil boiler should reach the same efficiency as a gas boiler. According to building regulations, oil boilers must have an energy rating of at least 86 per cent, or A+. A condensing oil fired boiler will usually have an efficiency of 90 per cent or higher. Oil is a more efficient fuel than gas.Get Price

  • AC drive for boiler feed pump - AC Drive - Variable

    Using the variable frequency control technology is one of the important methods to solve the problem. Controlling feed pump by AC drive can achieve the flow control in variable load. It solves the problem and improves the reliability of the system; furthermore, it decreases the throttle loss, reduces the wear and tear of the valve and damage on seal of the pipe, makes the equipment …Get Price

  • Operating characteristics of high pressure boiler feed

    1. Modern high-pressure boiler feed pump has two drive modes: one is the water pump driven by steam turbine special, its speed up to 5000 ~ 6000 rpm; the other is by the motor through gear speed after the feed pump driven by variable speed hydraulic coupling, it is as high as 5000 ~ …Get Price

  • High-Pressure Pumps, High-Speed Centrifugal Pumps, Boiler

    Coffin Turbo Pump, Inc. is a renowned manufacturer and global supplier of high-pressure, high-speed centrifugal pumps. Our high-pressure pump solutions utilize the most advanced high-speed motor and turbine drive designs in the pump industry for marine, offshore, military, waste-to-energy, pulp & paper, cogeneration.Get Price

  • Application of Boiler Feed Pumps in Combined Cycle

    Historical Perspective In the days of coal-fired power plants… Feed Pumps were Barrel Pumps Turbine Drive or Geared FC Drive High Speed 4500 to 6000 RPM 4-6 Stages Booster Pumps Common Base Loaded, Steady State Operation For a 500 MW Plant: Two 50% Pumps, ~4500 GPM Each 7500 Feet TDH Subcritical 11,500 Feet TDH SupercriticalGet Price

  • Boiler Feed Pump (BFP)

    variable-pressure once-through boilers, capable of main-taining high efficiency even in the middle-load area, go-ing mainstream. This situation required variable-speed motor drives, leading to the introduction of motor drives with a built-in speed increasing gear and a fluid coupling. Efforts to increase the thermal efficiency continued.Get Price

  • INTRODUCTION TO BOILER - 123seminarsonly.com

    INTRODUCTION TO BOILER A boiler is a closed vessel in which water or other fluid is heated. The heated or vaporized fluid of the boiler for use in various processes or heating applications Types of Boilers: Based on Principle of Working: 1. Fire tube boilers 2. …Get Price

  • MV Drive Solution for Boiler Feed Water Pump – Ethan Power

    Operating feed water pumps with variable speed drives can significantly increase the efficiency of a power plant. Outside the boiler feed-water pump's nominal range, the capacity needs to be sufficient to handle rare but possible abnormal situations in …Get Price

  • One small change in boiler feed level control, one massive

    At Grant's, Grundfos replaced the fixed-speed CR pumps for boiler feed with Grundfos iSOLUTIONS CRIE pumps with integrated variable speed drives. They also removed the modulating valve from the boiler. The CRE pump controls the level in the steam boilers, going up and down in speed depending on demand. At the same time, the Grundfos pumps use Get Price

  • VFDs driving the boiler feed water pump of #11-13 Combined

    consideration that the one variable frequency drive could drive 2 sets of pump as well as the by-pass function, two sets of variable frequency drive were arranged for the 2 sets of surplus heat boiler feed water system. In other words, 2 sets of VFD could drive 4 sets of pump. Detailed system diagram for the boiler feed water pump coldGet Price

  • Drive Solutions for Electric Utilities - TMEIC

    Application 1. Induced Draft Fan on Boiler Drive Applications in the Power Plant Variable frequency drives are used to control the speed of fans, pumps, and mills in power plants. VFDs are also used to smoothly start large motors, synchronize, and connect them across the line. The following seven pages describe fourGet Price

  • Coffin Turbo Pump, Inc. - Marship Engineering

    Boiler Feed Pumps Coffin Turbo Pump, Inc. Motor Driven Pumps Our motor drive pumps feature state of the art induction motors running at pump speeds and con-trolled by variable frequency drives. The motor and pump are flex coupled and mounted on a common base plate with a common lube system.. The VFD controller provides an en-Get Price

  • Implementation of Variable Frequency Drives (VFD) on

    6. The feed water pumps VVVF drives should cut in / cut out automatically depending on feed water demand. 7. In existing logic boiler drum level was being controlled by regulating the feed water flow through opening of control valves. In new logic, boiler feed water had to be controlled by changing the boiler feed pumps motor frequency.Get Price

  • Boiler Feed Engineering Manual - INSCO Group

    Sub system pumps such as dosing and water treatment pumps also exist. Boiler feed. When we talk boiler feed there is normally 4 ways to do it. • On/off control • Via feed valve • Via feed valve and variable speed • Variable speed They will all be described underneath here. Burner Deareat Boiler Steam Feed pump Condensate Smoke from boilerGet Price

  • VFD and Minimum Flow Valve - Pump engineering - Eng-Tips

    Mar 31, 2006 · We are looking into installing a Variable Frequency Drive for a Boiler Feed Pump. One of the issue is what to do with the minimum flow valve at the pump discharge. With VFD the pump may run at less than the discharge pr setting of the minimum flow valve in case of very low flow requirement, and the minimum flow valve may not operate at all.Get Price

  • Boiler Feed Unit: Pump Minimum Flow | R.L. Deppmann

    Feb 08, 2021 · Model numbers are B&G eSV boiler feed pumps. Design Flow Rate of the Pump. Once you select the required flow of the boiler or boilers being served, do not forget to add the minimum flow which will be a constant bypass. Example: The pump flow rate based on the boiler load is 48 GPM. The pump requires 9 GPM of minimum flow.Get Price

  • Reliable Speed Control. Geared Variable Speed Couplings

    The geared variable speed coupling is indispensable to thermal power plants. It is used as a continuous boiler feed pump drive (for example, in a 3 x 50% confi guration) with the best balance of energy. It is also used in start-up and stand-by solutions in conjunction with steam turbines. In these cases, itGet Price

Discount
7X24 Online