Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Removal of dissolved Oxygen from boiler feed water

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Removal of dissolved Oxygen from boiler feed water
  • Supply Capacity : 10 units/month :Removal of dissolved Oxygen from boiler feed water
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • 2. Assessment of total dissolved oxygen in different water

    7 Principle: Estimation of dissolved oxygen (DO) in water is useful in studying corrosion effect of boiler feed water and in studying water pollution. DO is usually determined by Winkler's titration method, which is based on the fact that DO oxidize potassium iodide (KI) to iodine (I 2).Since DO in water is in molecular state, as such it cannot oxidize KI.Get Price

  • DEAERATOR

    The removal of dissolved gases from boiler feedwater is an essential process in a steam system. The presence of dissolved oxygen in feedwater causes rapid localized corrosion in boiler tubes. Carbon dioxide will dissolve in water, resulting in low pH levels and the production of corrosive carbonic acid. Low pH levels in feedwater causeGet Price

  • Working Principle and Types - e Plant Maintenance

    Apr 15, 2019 · The removal of dissolved gasses from boiler feed water is an essential process in a steam system. The presence of dissolved oxygen in feed water causes rapid localized corrosion in boiler tubes. The dissolved Carbon dioxide in water, leads to low pH levels and the produces corrosive carbonic acid.Get Price

  • DRAFT BOILER/FEEDWATER GUIDELINES

    3.2.2 Dissolved oxygen can be eliminated in a boiler system by utilizing a deaerator feed tank, heated feedwater, or treating the feedwater in the condensate tank. Introducing an oxygen scavenger into the feedwater system will also help eliminate any …Get Price

  • Sulfites for Oxygen Control - Scranton Associates

    The amount of oxygen scavenger required in a boiler water is related to the concentration of dissolved oxygen, the residual level of scavenger specified, and the percent of blow down performed. Water temperature, water composition, and reaction time also have considerable impact on the ultimate quantity of scavenging chemical neededGet Price

  • Boiler Feed Water Degasification Using Membrane …

    Membrane Contactors have been used to remove dissolved oxygen in boiler feed water systems for years. This report reviews various system designs and discusses how Membrane Contactors can be optimized in boiler feed water applications for removal of …Get Price

  • BOILER FEED AND CONDENSATE RECOVERY SYSTEMS

    boiler tubes from oxygen corrosion. Saves Fuel and Reduces Water Use Permits recovery of valuable, high-purity, pretreated condensate return to be used as boiler feedwater. Saves Fuel and Reduces Chemical Use By using mostly mechanical means rather than purely chemical methods to remove dissolved oxygen from the feedwater, theGet Price

  • Effect of Dissolved Gases in Feed Water - Forbes Marshall

    Deaerator System. The DeOxy deaerator removes dissolved gases such as oxygen in the boiler feedwater. It allows substantial savings in the use of chemicals and in the number of blowdowns required. A deaerator will prevent the corrosion in the system and in the boiler. Oxygen is the main cause of corrosion found in steam systems.Get Price

  • water technology 3 - Engineer's katta engineering chemistry

    Jan 25, 2022 · Deaerator is a mechanical equipment that removes dissolved gases mainly dissolved oxygen & other non-condensable gases from boiler feed water. Oxygen causes pitting type corrosion in feed water systems. The process of removing dissolved gases from water also known as mechanical Deaeration.Get Price

  • BOILER DISSOLVED OXYGEN CONTROL

    Removal of dissolved oxygen from water: A comparison of four common Get Price

  • NOTES Unit 1 Water Technology 23022021 | PDF | Sodium

    Dissolved oxygen in water in the presence of prevailing high temperature, Presence of NaOH in boiler feed water Caustic embrittlement is a type of boiler corrosion caused by using highly alkaline water in the boiler. Removal of salts from sea water,to get pure water.Get Price

  • Deaerator – Principle, Types, Process Control, Purpose

    Deaerator solves the purpose of removal of unwanted dissolved gases and dissolved oxygen from the boiler feed water before entering into boilers. Most of the deaerators are designed in such a way that the dissolved oxygen content in the outlet water is about 7 ppb wt% De-aerator works based on Henry's Law and Inverse Solubility of Water Get Price

  • Boiler Water Chemistry | Integra Water

    Oxygen Removal. The addition of oxygen to a system with feed water and heat will initiate corrosion. Heat accelerates the oxygen corrosion if the oxygen is not removed from the feedwater system and boiler water; An oxygen scavenger is used to eliminate the remaining oxygen. Properly applied, oxygen scavengers will prevent oxygen pittingGet Price

  • Boiler Corrosion - Causes,Effects and How to Prevent it

    Apr 29, 2020 · 2. Removal of dissolved oxygen 3. High PH value of boiler water 4. Mechanical deaeration of boiler water 5. Higher feed water temperature i.e. reduces its oxygen content. 6. Chemical de-oxygenation by use of oxygen scavengers i.e. sodium sulphite 7. Hot condensate return as it contains less O2 then feed water and also saves fuel.Get Price

  • Water Handbook - Boiler Feedwater Deaeration | SUEZ

    Boiler water DO removal Dissolved Oxygen removal from any steam and water system is of major importance. The first step is typically mechanical deaeration which is economical and serves to also eliminate other corrosive gases such as ammonia and carbon dioxide. A properly operated deaerator can reduce dissolved oxygen to as low as 10 µg/L (10 ppb).Get Price

  • What is the best way to remove dissolved oxygen from a

    In this article, a review of the methods of removing dissolved oxygen in the feed water of a boiler. A degasser simulation, used to reduce the dissolved oxygen content in the water, was carried Get Price

  • Boiler Water Treatment Chemicals, Feed, and Control

    The total calculation equation to remove residual oxygen and provide a boiler water residual is: (Feedwater O 2 x 7.88) + (1.6 x Boiler Water SO 3 Residual) / Feedwater Cycles = Feedwater Dosage of sodium sulfite in ppm. Spreadsheets can be made as shown at the end of the article that illustrate theGet Price

  • Boiler Water Treatment - Association of Water Technologies

    Feed Water Tank Water temperature is important for oxygen removal. With this system, the temperature limitation is feed water pump cavitation. When the feed water pump activates, the boiling point of water is reduced Feed the oxygen scavenger to the water section of the tank using a stainless steel quill. Cold Makeup Condensate HeatGet Price

  • Explained: How Does a Deaerator Work? - Boiler Water …

    In a bubbling device deaerator, oxygen is removed following preheating of the water, through intimate contact of steam and water moving over perforated plates. Deaerating Condensers In power generating stations, main turbine condensers have air ejectors to remove dissolved gases. Sometimes the pressure deaerator is omitted from the feedwater cycle.Get Price

  • 13_Oxygen Removal From Boiler Water - DocShare.tips

    Oxygen removal from boiler water in high pressure boilers Abstract The most frequently encountered corrosion problems results from exposure of boiler metal to dissolved oxygen. Breakdown of the magnetite layer is almost because of mechanical and thermal stresses induced during boiler start up or shutdown. The presented study is related to Get Price

  • Boiler Feedwater Deaeration: How To Keep Your Steam System

    The feed water is sprayed into a stream of 5 psig steam for efficient heat transfer and subsequent oxygen removal. Return condensate is distributed on a tray to generate flash steam. The flash steam helps remove any residual oxygen in the condensate return, as well as …Get Price

  • Removal of dissolved gases for boiler feed water

    We claim: 1. A method for removing dissolved gases from a water feed in a catalytic steam reforming process, the method comprising: (a) heating a first portion or all of a boiler feed water stream in a heat exchanger by indirect heat transfer with at least one of a reformate stream from the catalytic steam reforming process and a combustion product gas stream from the catalytic …Get Price

  • Membrane contractors reduce chemical use and blowdowns

    Oct 01, 2003 · The feed water flow rate is the amount of water that is added to the boiler. The feed water rate is equal to the boiler capacity + water loss in blow down – condensate return. Chemical costs are directly associated to the gallons of water treated and the inlet dissolved oxygen level in the feed water.Get Price

  • Hydrogen embrittlement in boilers - Lenntech

    Recently membrane contractors have been utilized to remove the dissolved gasses (O 2 and CO 2) in boiler feed water.Widely used in the semiconductor, power, pharmaceutical and other industries to control dissolved gasses in water systems, their use in boiler feed water degasification systems has grown steadily since the development of new industrial grade …Get Price

  • CHEMISTRY WATER TECHNOLOGY 2 - Engineer's katta ENGG CHEM

    The removal of oxygen by heating (e.g direct steam injection) reduces the requirement of expensive oxygen scavenging chemicals (most often sodium sulphite), the addition of which actually leads up to increased feed water TDS and longer blowdowns. Direct seam injection is one of the most efficient methods for boiler feed tank heating.Get Price

  • Membrane Degassing to Remove Dissolved Gases > PRD Tech

    Aug 02, 2016 · Degassing is removing dissolved gases from liquids. Applications includes: Removing biogenic hydrogen sulfide from. groundwater, used for drinking water. Removing carbon dioxide from water used. for regenerating ion exchange resins. Removal of dissolved oxygen from boiler feed water. Removing ammonia from wastewater.Get Price

  • Removal of dissolved oxygen from water: A comparison …

    The solubility of non-condensable gases (O2 and CO2) in water is very low. Eventhough they should be completely removed before entering the boiler to protect it from corrosion.Dearator temperature and pressure specify the oxygen content. The lower the deaerators pressure the lower oxygen content in the water phase [1]. Deaerator operating conditionGet Price

  • Dissolved Oxygen Test Kits – Boiler Feedwater | CHEMetrics

    Dissolved oxygen, or DO, is one of the most important water quality parameters to control in a boiler system. It is the primary corrosive agent of steam-generating systems. Even low concentrations of DO can be highly destructive, causing localized corrosion and pitting of metal system components.Get Price

  • Monitoring Dissolved Oxygen in High-Pressure Boiler Systems

    performance. Proper water quality maintenance maximizes operating efficiency and the lifespan of boiler equipment. Maintaining Water Quality in High-Pressure Boilers . Dissolved oxygen, or DO, is one of the most important water quality parameters to control in a boiler system. It is the primary corrosive agent of steam-generating systems.Get Price

  • What is a Boiler Deaerator and How Does It Operate? - MPC

    Feb 08, 2022 · Deaerator manufacturers state that properly operating deaerators can reduce dissolved oxygen concentrations in feed water to 0.005 cc per liter, or 7 ppb, and 0 free carbon dioxide. However, plant oxygen levels vary from 3 to 50 ppb, which makes chemical removal of oxygen in feed water with oxygen scavengers necessary.Get Price